Insulating materials must not promote corrosion to steel when wet. UN2258, 1,2-Propylenediamine: In HM-260B, PHMSA removed special provision A6 from column (7) of the . Molten sulfur must be marked as required by 172.325 of this subchapter. here. In addition, a container exceeding 4 fluid ounces volumetric capacity (7.22 cubic inches) or containing more than 65 grams of fuel may not be connected or manifolded to a lighter or similar device and must also be described and packaged according to the fuel contained therein. The rechargeable lithium ion cells can only be charged from the primary lithium metal cells; ii. Non-specification bulk bins are authorized. The guns are packaged in accordance with Packing Method US 1 as specified in 173.62 of this subchapter. For transportation by aircraft, cargo transport units may only be offered for transportation and transported under conditions approved by the Associate Administrator. A3 For combination packagings, if glass inner packagings (including ampoules) are used, they must be packed with absorbent material in tightly closed rigid and leakproof receptacles before packing in outer packagings. (a) General. Navigate by entering citations or phrases 28 The dihydrated sodium salt of dichloroisocyanuric acid does not meet the criteria for inclusion in Division 5.1 (Oxidizer) and is not subject to the requirements of this subchapter unless meeting the criteria for inclusion in another class or division. N95 UN1075, Liquefied petroleum gas and UN1978, Propane authorized for transport in DOT 4BA240 cylinders is not subject to the UN identification number and proper shipping name marking or the label requirements of this part subject to the following conditions: a. B7 Safety relief devices are not authorized on multi-unit tank car tanks. When a special provision specifies packaging or packaging requirements - Your Nuclear Attack Map for 2023 - mirasafety.com 117 If shipment of the explosive substance is to take place at a time that freezing weather is anticipated, the water contained in the explosive substance must be mixed with denatured alcohol so that freezing will not occur. TP30 This hazardous material may only be transported in insulated tanks. B80 Each cargo tank must have a minimum design pressure of 276 kPa (40 psig). 422 When labelling is required, the label to be used must be the label shown in 172.447. 337 Authorizes the use of regulated waste containers manufactured prior to October 1, 2006 to be marked with the alternative shipping name of Regulated medical waste, UN3291 and arrows that deviate as prescribed in 172.312(a)(2) in that they may be black or white. The articles may be transported as in Division 1.4 Compatibility Group D (1.4D) if all of the conditions specified in 173.63(a) of this subchapter are met. Tank car tanks must have a test pressure rating of 1,379 kPa (200 psig). Component cells of the battery must be of a type proved to meet the respective testing requirements of the Manual of Tests and Criteria, part III, subsection 38.3 (IBR, see 171.7 of this subchapter). Lithium ion cells and batteries at a state of charge greater than 30 percent of their rated capacity may only be transported under conditions approved by the Associate Administrator in accordance with the requirements in 49 CFR part 107, subpart H. Guidance and methodology for determining the rated capacity can be found in sub-section 38.3.2.3 of the UN Manual of Tests and Criteria (IBR, see 171.7 of this subchapter). B82 Cargo tanks and portable tanks are not authorized. Column 1 specifies the T Code. Table 3 authorizes Large Packagings for specific proper shipping names through the use of IB Codes assigned in the 172.101 table of this subchapter. For Federal Register citations affecting 172.102, see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume and at www.govinfo.gov. B33 MC 300, MC 301, MC 302, MC 303, MC 305, MC 306, and DOT 406 cargo tanks equipped with a 1 psig normal vent used to transport gasoline must conform to Table I of this Special Provision. 52 This entry may only be used for substances that are too insensitive for acceptance into Class 1 (explosive) when tested in accordance with Test Series 2 in the UN Manual of Tests and Criteria, Part I (incorporated by reference; see 171.7 of this subchapter). 166 When transported in non-friable tablet form, calcium hypochlorite, dry, may be transported as a Packing Group III material. The requirements of 173.24(g)(1) and 173.27(c) do not apply. The mixture for emulsions typically has the following composition: 60-85% ammonium nitrate; 5-30% water; 2-8% fuel; 0.5-4% emulsifier or thickening agent; 0-10% soluble flame suppressants; and trace additives. Each inner packaging contains not more than 30 mL; b. 5101-5128, 44701; 49 CFR 1.81, 1.96 and 1.97. The requirements of 173.24(g)(1) and 173.27(c) do not apply. (7) The design type of the article must be subjected to the following test. In addition, MC 312 and DOT 412 cargo tank motor vehicles must: a. The unintended errors are summarized below. 21 This material must be stabilized by appropriate means (e.g., addition of chemical inhibitor, purging to remove oxygen) to prevent dangerous polymerization (see 173.21(f) of this subchapter). The pressure relief device must be preceded by a frangible disk in accordance with the requirements in 178.275(g)(3) of this subchapter to prevent crystallization of the product in the pressure relief device. TP2 a. B25 Packagings must be made from monel or nickel or monel-lined or nickel-lined steel. N25 Steel single packagings are not authorized. A7 Steel packagings must be corrosion-resistant or have protection against corrosion. Tables 1, 2, and 3 follow: 1 Flexible plastic (51H) Large Packagings are only authorized for use with flexible inner packagings. A37 This entry applies only to a material meeting the definition in 171.8 of this subchapter for self-defense spray. For UN 3176, this requirement only applies when the hazardous material reacts dangerously with water. A chemical under pressure packaged in an aerosol dispenser must be transported under UN1950. TP27 A portable tank having a minimum test pressure of 4 bar (400 kPa) may be used provided the calculated test pressure is 4 bar or less based on the MAWP of the hazardous material, as defined in 178.275 of this subchapter, where the test pressure is 1.5 times the MAWP. Thickness of stainless steel for tank shell and heads for cargo tanks and portable tanks must be the greater of 6.35 mm (0.250 inch) or the thickness required for a tank with a design pressure at least equal to 1.3 times the vapor pressure of the lading at 46 C (115 F). If a tank car tank is equipped with a non-reclosing pressure relief device, the rupture disc must be perforated with a 3.2 mm (0.13 inch) diameter hole. Each tank must be equipped with pressure relief devices conforming to the following requirements: 1 Total venting capacity in standard cubic feet hour (S.C.F.H.) 420 This entry does not apply to manufactured articles (such as table tennis balls). N37 This material may be shipped in an integrally-lined fiber drum (1G) which meets the general packaging requirements of subpart B of part 173 of this subchapter, the requirements of part 178 of this subchapter at the packing group assigned for the material and to any other special provisions of column 7 of the 172.101 table. - Other Regulations Relating to Transportation, - Pipeline and Hazardous Materials Safety Administration, Department of Transportation, - Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, Emergency Response Information, Training Requirements, and Security Plans, - Table of Hazardous Materials and Special Provisions, https://www.ecfr.gov/current/title-49/subtitle-B/chapter-I/subchapter-C/part-172/subpart-B/section-172.102. 430 This entry shall only be used for solid medical waste of Category A transported for disposal. TP32 Portable tanks may be used subject to the following conditions: a. quantity (RQ)", contains the reportable quantity (RQ), in pounds and kilograms, for each hazardous substance listed in Column 1 of TABLE 1. (2) A code containing the letter A refers to a special provision which applies only to transportation by aircraft. Determining Authorized Packaging for the Transportation of a Hazardous Solid substances transported or offered for transport above their melting point are authorized for transportation in portable tanks conforming to the provisions of portable tank instruction T4 for solid substances of packing group III or T7 for solid substances of packing group II, unless a tank with more stringent requirements for minimum shell thickness, maximum allowable working pressure, pressure-relief devices or bottom outlets are assigned in which case the more stringent tank instruction and special provisions shall apply. However, the design stress limits may not exceed 25 percent of the stress for 0 temper at the maximum design temperature of the cargo tank, as specified in the Aluminum Association's Aluminum Standards and Data (IBR, see 171.7 of this subchapter). TP17 Only inorganic non-combustible materials may be used for thermal insulation of the tank. B49 Tanks equipped with interior heater coils are not authorized. g. The test results shall be documented, shall be traceable, and shall be made available to a representative of the Department upon request. (3) When no bottom openings are authorized, the alternative portable tank must not have bottom openings. Hazardous Materials Tables | High Road Online CDL Training - TruckingTruth It must be demonstrated that the article relieves its pressure by means of a fire degradable seal or other pressure relief device, in such a way that the pressure receptacle will not fragment and that the article or fragments of the article do not rocket more than 10 meters; and. learn more about the process here. In addition, for solid materials, special provision B54 applies. The purpose of this article is to explain the meaning of the coding system for the Special Provisions of column 7 in order to facilitate your review and understanding of them and how they may apply to your shipment of a hazardous material. For UN2031 with more than 55% nitric acid, rigid plastic IBCs and composite IBCs with a rigid plastic inner receptacle are authorized for two years from the date of IBC manufacture. 150 This description may only be used for ammonium nitrate-based fertilizers. A bulk packaging containing sulfur is not subject to the placarding requirements of subpart F of this part, if it is marked with the appropriate identification number as required by subpart D of this part. 70 Black powder that has been classed in accordance with the requirements of 173.56 of this subchapter may be reclassed and offered for domestic transportation as a Division 4.1 material if it is offered for transportation and transported in accordance with the limitations and packaging requirements of 173.170 of this subchapter. Column 2 specifies the minimum test pressure, in bar (1 bar = 14.5 psig), at which the periodic hydrostatic testing required by 180.605 of this subchapter must be conducted. The receptacle must contain no hazardous materials other than the liquid nitrogen which must be fully absorbed in a porous material in the receptacle. B47 Each tank may have a reclosing pressure relief device having a start-to-discharge pressure setting of 310 kPa (45 psig). This entry does not apply to capacitors that by design maintain a terminal voltage (e.g., asymmetrical capacitors.). 371 a. An unused lighter or a lighter that is cleaned of residue and purged of vapors is not subject to the requirements of this subchapter. N12 Plastic packagings are not authorized. Special provisions contain packaging provisions, prohibitions, exceptions from requirements for particular quantities or forms of materials and requirements or prohibitions applicable to specific modes of transportation, as follows: (1) A code consisting only of numbers (for example, 11) is multi-modal in application and may apply to bulk and non-bulk packagings. Column 7 Lists the additional (special) provisions that apply to this material. b. This includes hybrid electric vehicles powered by a fuel cell, an internal combustion engine, and wet, sodium or lithium batteries installed. The toy plastic or paper caps must be in the form of sheets, strips, rolls, or individual caps; b. N11 This material is excepted for the specification packaging requirements of this subchapter if the material is packaged in strong, tight non-bulk packaging meeting the requirements of subparts A and B of part 173 of this subchapter. This provision may be used for both domestic and international shipments. (2) They must be packed in strong outer packagings and the completed package must be capable of withstanding a 1.8 meter (5.9 feet) drop without leakage of gas contents from detectors. FAR). Specification 110A500W tanks must be stainless steel. 108 Fireworks must be so constructed and packaged that loose pyrotechnic composition will not be present in packages during transportation. The present arrangement occurs in such a way that one QA molecule is hydrogen-bonded to four neighboring molecules: two different molecules in one column and other two molecules in another column. A 25 mm (1 inch) woven lining of asbestos or other approved material must be placed between the bolster slabbing and the bottom of the tank. Interpretation Response | PHMSA - Pipeline and Hazardous Materials If a vehicle is powered by a flammable liquid and a flammable gas internal combustion engine, it must be described using Vehicle, flammable gas powered. This includes hybrid electric vehicles powered by both an internal combustion engine and wet, sodium or lithium batteries installed. TP4 The maximum degree of filling for portable tanks must not exceed 90%. Cargo heaters must be reverse refrigeration (heat pump) units. Amdt. Using the nominal capacitance (CN), rated voltage (UR) and the rated lower limit voltage (UL). TP22 Lubricants for portable tank fittings (for example, gaskets, shut-off valves, flanges) must be oxygen compatible. Heater pipes must be of welded construction designed for a test pressure of 500 psig. TP40 The portable tank must not be transported when connected with spray application equipment. Note also that this exception does not apply to batteries that have been reconditioned for reuse. N32 Aluminum materials of construction are not authorized for single packagings. A5 Solids having an inhalation toxicity of Packing Group I are not permitted on passenger aircraft and may not exceed a maximum net quantity per package of 15 kg (33 pounds) on cargo aircraft. Radiation detection systems containing such detectors are not subject to any other requirements of this subchapter provided they are packed in accordance with paragraph c of this special provision. B4 MC 300, MC 301, MC 302, MC 303, MC 305, and MC 306 and DOT 406 cargo tanks are not authorized. Regulation Y (iii) Constructing the battery with terminals that are recessed or otherwise protected so that the terminals will not be subjected to damage if the package is dropped. Hazardous materials necessary for the safe and proper operation of the cargo transport unit (e.g., fire extinguishing systems and air conditioning systems), must be properly secured to or installed in the cargo transport unit and are not otherwise subject to this subchapter. B81 Venting and pressure relief devices for tank car tanks and cargo tanks must be approved by the Associate Administrator. N85 Packagings certified at the Packing Group I performance level may not be used. In making this determination factors to be taken into consideration include, but are not limited to, the capacity and geometry of the packaging and the effect of any insulation present, the temperature of the material when offered for transport, the duration of the journey, and the ambient temperature conditions typically encountered in the journey (considering also the season of year), the effectiveness and other properties of the stabilizer employed, applicable operational controls imposed by regulation (e.g., requirements to protect from sources of heat, including other cargo carried at a temperature above ambient) and any other relevant factors. 56 A means to interrupt and prevent detonation of the detonator from initiating the detonating cord must be installed between each electric detonator and the detonating cord ends of the jet perforating guns before the charged jet perforating guns are offered for transportation. When a special provision specifies packaging or packaging requirements -, (1) The special provision is in addition to the standard requirements for all packagings prescribed in 173.24 of this subchapter and any other applicable packaging requirements in subparts A and B of part 173 of this subchapter; and. f. The properties of mechanical strength mentioned in this special provision shall be tested using a prototype of a receptacle and/or dispenser filled to nominal capacity, by increasing the temperature until the specified pressures are reached. In addition, the column 5 reference is modified to read III on those occasions when this material is offered for transportation or transported by highway or rail. 347 Effective July 1, 2011, for transportation by aircraft, this entry may only be used if the results of Test series 6(d) of Part I of the UN Manual of Tests and Criteria (IBR, see 171.7 of this subchapter) have demonstrated that any hazardous effects from accidental functioning are confined to within the package. B78 Tank cars must have a test pressure of 4.14 Bar (60 psig) or greater and conform to Class 103, 104, 105, 109, 111, 112, 114 or 120. Refrigerated liquefied gases that are authorized to be transported in portable tanks are specified in tank instruction T75. Energy storage capacity means the energy stored in a capacitor, as calculated according to the following equation. Portable tank instructions T1 through T22 specify the applicable minimum test pressure, the minimum shell thickness (in reference steel), bottom opening requirements and pressure relief requirements. A51 For aircraft batteries, irrespective of the quantity limitations specified in Column (9A) of the 172.101 Table or 175.75(c), wet cell batteries, UN2794 or UN2795, up to a limit of 100 kg net mass per package may be transported aboard passenger aircraft. will also bring you to search results. Be ASME Code (U) stamped for 100% radiography of all pressure-retaining welds; b. These articles must be tested in accordance with Test series 6(c) of Part I of the UN Manual of Tests and Criteria (incorporated by reference; see 171.7 of this subchapter), with no explosion of the device, no fragmentation of device casing or pressure vessel, and no projection hazard or thermal effect that would significantly hinder fire-fighting or other emergency response efforts in the immediate vicinity. B3 MC 300, MC 301, MC 302, MC 303, MC 305, and MC 306 and DOT 406 cargo tanks and DOT 57 portable tanks are not authorized. b. N40 This material is not authorized in the following packagings: a. A100 Lithium ion cells and batteries must be offered for transport at a state of charge not exceeding 30 percent of their rated capacity. B59 Water-tight, sift-proof, closed-top, metal-covered hopper cars are also authorized provided that the lading is covered with a nitrogen blanket. Portable tank instructions specify the requirements applicable to a portable tank when used for the transportation of a specific hazardous material. Ammonia solutions may be transported in rigid or composite plastic IBCs (31H1, 31H2 and 31HZ1) that have successfully passed, without leakage or permanent deformation, the hydrostatic test specified in. 105 The word Agents may be used instead of Explosives when approved by the Associate Administrator. 136 This entry applies only to articles, machinery, and apparatus containing hazardous materials as an integral element of the article, machinery, or apparatus. Alternatively, the item itself may be used as a packaging if it meets the general packaging requirements of subparts A and B of part 173 of this subchapter. N43 Metal drums are permitted as single packagings only if constructed of nickel or monel. 61 A chemical oxygen generator is spent if its means of ignition and all or a part of its chemical contents have been expended. a. Mixtures of one or more organic lead mixtures (such as tetraethyl lead, triethylmethyl lead, diethyldimethyl lead, ethyltrimethyl lead, and tetramethyl lead) with one or more halogen compounds (such as ethylene dibromide and ethylene dichloride), hydrocarbon solvents or other equally efficient stabilizers; or. 167 These storage systems must always be considered as containing hydrogen. Thickness of stainless steel for portable tank shells and heads must be the greater of 6.35 mm (0.250 inch) or the thickness required for a portable tank with a design pressure at least equal to 1.3 times the vapor pressure of the hazardous material at 46 C (115 F). If one of the components, which can be a pure substance or a mixture, is classed as flammable, the chemical under pressure must be classed as flammable in Division 2.1. A copy of the approval must accompany each shipment. B18 Open steel hoppers or bins are authorized. The Meaning of the Symbols in Column 7 of the Hazardous Materials Table Portable tanks must be hydraulically tested and internally inspected at intervals not exceeding 2.5 years. 37 Unless it can be demonstrated by testing that the sensitivity of the substance in its frozen state is no greater than in its liquid state, the substance must remain liquid during normal transport conditions. N42 1A1 drums made of carbon steel with thickness of body and heads of not less than 1.3 mm (0.050 inch) and with a corrosion-resistant phenolic lining are authorized for stabilized benzyl chloride if tested and certified to the Packing Group I performance level at a specific gravity of not less than 1.8. developer resources. When portable tank instruction T75 is referenced in Column (7) of the 172.101 Table, the applicable refrigerated liquefied gases are authorized to be transported in portable tanks in accordance with the requirements of 178.277 of this subchapter. 57 Maneb or Maneb preparations stabilized against self-heating need not be classified in Division 4.2 when it can be demonstrated by testing that a volume of 1 m3 of substance does not self-ignite and that the temperature at the center of the sample does not exceed 200 C, when the sample is maintained at a temperature of not less than 75 C 2 C for a period of 24 hours, in accordance with procedures set forth for testing self-heating materials in the UN Manual of Tests and Criteria (IBR, see 171.7 of this subchapter). TP29 A portable tank having a minimum test pressure of 1.5 bar (150.0 kPa) may be used provided the calculated test pressure is 1.5 bar or less based on the MAWP of the hazardous materials, as defined in 178.275 of this subchapter, where the test pressure is 1.5 times the MAWP. B77 Other packaging are authorized when approved by the Associate Administrator. 9 Packaging for certain PCBs for disposal and storage is prescribed by EPA in 40 CFR 761.60 and 761.65. N80 Packages consisting of one inner metal can, not over 2.5 kg (5.5 pounds) capacity, packed in an outer wooden or fiberboard box, or a wooden barrel, are authorized and need not conform to the requirements of part 178 of this subchapter. (1) Even though certain packagings are specified in this part, it is, nevertheless, the responsibility of the person offering a hazardous material for transportation to ensure that such packagings are compatible with their lading. 382 Packages containing toy plastic or paper caps for toy pistols described as UN0349, Articles, explosive, n.o.s. A current copy of CGA pamphlet, CGA C-6 must be available at the facility servicing the life-saving appliance. Flexible, fiberboard or wooden IBCs must be sift-proof and water-resistant or be fitted with a sift-proof and water-resistant liner. No label is needed where the table shows the word NONE. (3) B codes. Rigid plastics: 11H1, 11H2, 21H1 and 21H2, c. Composite with plastic inner receptacle: 11HZ1, 11HZ2, 21HZ1 and 21HZ2, e. Wooden: 11C, 11D and 11F (with inner liners). (3) A flammable gas is a gas that meets the criteria in 173.115 of this subchapter. Thickness of stainless steel for tank shell and heads must be the greater of 7.62 mm (0.300 inch) or the thickness required for a portable tank with a design pressure at least equal to 1.5 times the vapor pressure of the hazardous material at 46 C (115 F). 172-29, 41 FR 15996, Apr. When a plus sign is assigned to mix- 147 This entry applies to non-sensitized emulsions, suspensions, and gels consisting primarily of a mixture of ammonium nitrate and fuel, intended to produce a Type E blasting explosive only after further processing prior to use. These special provisions are in addition to the standard packaging requirements. 170 Air must be eliminated from the vapor space by nitrogen or other means. (h) Column 7: Special provisions. When column 7 of the Hazardous Materials Table (49 CFR 172.101) includes a special provision code for an entry in the table, the requirement of that code - or codes, there may be several of them - is in addition to the general packaging requirements of 173.24 and any other applicable packaging requirements in Part 173. Transport vehicles must be vented to prevent accumulation of vapors at a poisonous or flammable concentration. 8 A hazardous substance that is not a hazardous waste may be shipped under the shipping description Other regulated substances, liquid or solid, n.o.s., as appropriate. These requirements must be met in addition to the design and construction specifications in part 178 of this subchapter. Columns 8A, 8B and 8C specify the applicable sections for . ; and. For non-pressurized lighters containing a Class 3 (flammable liquid) material, its design, description, and packaging must be approved by the Associate Administrator prior to being offered for transportation or transported in commerce. 165 These substances are susceptible to exothermic decomposition at elevated temperatures. A10 When aluminum or aluminum alloy construction materials are used, they must be resistant to corrosion. Uranium hexafluoride may be classified under this entry only if the conditions of 173.420(a)(4) and (6) and (d) and 173.421(b) and (d) of this subchapter, and, for fissile-excepted material, the conditions of 173.453 of this subchapter are met. This is an automated process for The consignor shall be in possession of a copy of each applicable certificate when packages include fissile material excepted by competent authority approval. These mixtures may be classified in Division 4.1 when tested in accordance with test series 6(c) of the UN Manual of Tests and Criteria (IBR, see 171.7 of this subchapter) and approved by the Associate Administrator. (i) These provisions apply to the transportation of hazardous materials in UN portable tanks. 3 This material is poisonous by inhalation (see 171.8 of this subchapter) in Hazard Zone C (see 173.116(a) of this subchapter), and must be described as an inhalation hazard under the provisions of this subchapter. Each reference in this column to a material which is a hazardous waste or a hazardous substance, and whose proper shipping name is preceded in Column 1 of the Table by the letter "A" or "W", is modified to include " 173.203" or " 173.213", as appropriate for liquids and solids, respectively, on those occasions when the .